HVACControlsZoning ControlsHoneywellTrueZONE Zoning Control Kit

TrueZONE Zoning Control Kit, With HZ432 Zone Control Panel, AT140 Transformer and C7735A Discharge Air Temperature Sensor, For Conventional, Heat Pump or Dual Fuel Applications Up To 32 Zones (3H/2C)
RESIDEO

Part #:

244142

Model #:

HZ432K/U
Login to view Pricing & Availability
MFG Number 0904
Box Quantity 1
Date Added 2008-02-26
Replaced By
RHS Price Page 24-34

Additional Information
Logo Honeywell.tif
Contact Rating @ 24 Vac 8.5 VA Maximum
Frequency 50/60 Hz
Includes HZ432 Zone Control Panel, AT140 Transformer, C7735A Discharge Air Temperatu
Number of Zones 4 Expandable
Operating Ambient Temperature Range -40° to 165°F (-40° to 74°C)
Operating Humidity Range 5% to 90% RH Non-Condensing
Shipping Ambient Temperature Range -20° to 150°F (-29° to 66°C)
Stages 3 Heat/2 Cool
Voltage 24 VAC

Features:

·   Intuitive Installer setup. Easy-to-follow, digital display uses real language to guide installer through four easy steps.

·   Standard Checkout Procedure

·   Robust Push Terminals

·   Common-Sense LEDs

·   Clean, Professional Installation

·   Variable-Speed Fan Control

·   Discharge Air Temperature Staging

·   Advanced Dual-Fuel Operation

·   Use with TAZ-4 Add-A-Zone to expand to 32 zones

·   RedLINK enabled for up to 4 wireless zones when used with THM4000R1000 Wireless Adapter

·   Heat Pump Compatible

·   Auto Changeover

·   Emergency Heat Switch

·   Resettable Fuse

·   Individual Zone Fan Control

·   Input Ratings: 18-30 VAC 50/60 Hz powered by a transformer of 40 VA or more

·   Wiring: 18- or 20-gauge solid (not stranded) wire

·   Mounting: Mounts with either 2 user-supplied screws at center line to mount onto 2 x 4, or with 4 screws at corners for wall mount.

 

Application:

·   Single-stage, multi-stage, conventional, or heat pump heat/ cool HVAC equipment up to 3 stages of heat and 2 stages of cool;

·   Dual-fuel systems with up to 2 heat pump stages and 2 fossil fuel stages;

·   2, 3, or 4 zones and is expandable to 32 zones using wired thermostats with the optional TotalZone Add-A-Zone Panel;

·   2, 3, or 4 zones with wireless thermostats when used with the optional wireless adaptor.