HVACHVAC Valves & AccessoriesSmart ValvesTempstarSV9641M4510

SmartValve Control Intermittent Hot Surface Pilot Ignition, 3/4" NPT x 3/4" NPT
TEMPSTAR

Part #:

050580

Model #:

SV9641M4510
Discontinued Available While Supplies Last
Login to view Pricing & Availability
MFG Number 0604
Box Quantity 1
Date Added 2001-06-29
Replaced By 097668
RHS Price Page 05-9A

Additional Information
id 3217
item 050580
mfgno 0604
adddate 2001-06-29
Logo ICP_logo.tif
Control Voltage 24 Vac
Electrical Ratings 24 Vac
Frequency 60/50 Hz
Pressure
Tapping 1/8 in. - NPT
Ratings (psi) 1/2 psi
Ambient Temp Range °F(°C) -40°F to +175°F(-40°C to +79° C)
Body Pattern Straight-through
Cool Fan Off Delay adj. 30, 60 sec (set at 30 sec)
Cool Fan On Delay adj. 4, 30 sec (set at 4 sec)
Dimensions Wide x High x Long (in) 3.2 x 4.9 x 4.1
Flame Failure Response Time (sec) 1.6 sec @ 3 µA
Flame Sense Two Rod
Heat Fan Off Delay adj. 60, 120, 150, 180 sec (set at 120 sec)
Heat Fan On Delay adj. 30, 60 sec (set at 30 sec)
Ignition Sequence Intermittent Pilot
Ignition Source Pilot
Ignition System Type Intermittent Hot Surface Pilot Ignition
Ignition Trial Time (sec) 90 sec
Ignition Trials To Lockout continuous retry
Includes Two 3/4 in. x 1/2 in. reducer bushings and an LP conversion kit.
Inlet/Outlet Size (in) 3/4 in. NPT x 3/4 in. NPT.
Maximum Capacity (ft³/hr) 415 ft³/hr
Maximum Capacity at 1 in PD (ft³/hr) 300 ft³/hr
Minimum Capacity (ft³/hr) 30 ft³/hr
Opening Characteristics (standard, step) Standard Opening
Post Purge 30 seconds
PrePurge 15 seconds
Pressure Regulator Setting (psi) 3.5 in. wc

Features:

·   Communicates directly with an electronic fan timer (ST9160 Electronic Fan Timer for single stage applications; ST9162 Electronic Fan Timer for two-stage applications) in typical forced warm air furnace applications.

·   Also interfaces with the 208907 Terminal Board, providing compatibility with power stealing thermostats. Or, they directly interface with the appropriate power supplies and a system thermostat for additional appliance applications.

·   When controlled directly by a thermostat, these controls do not provide a postpurge function, because power to the control is removed when the thermostat call for heat ends.

·   The SV9641 Systems are suitable for a wide range of fan-assisted combustion gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, water heaters and commercial cooking appliances.

·   Standard opening and 3.5 in. wc pressure regulator settings

Mounting:

·   0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.