HVACControlsIgnition Controls & ModulesWhite RodgersUniversal Non-Integrated HSI Ignition Module

Universal Hot Surface Ignition Module, Carbide, Non-Integrated
WHITE RODGERS

Part #:

097828

Model #:

50E47-843S1
Login to view Pricing & Availability
MFG Number 1010
Box Quantity 20
Date Added 2003-07-03
Replaced By
RHS Price Page 57-35
Document Download Documents\50E47-843 Universal Non-Integrated HSI Ignition Module_D.doc

Features:

·   Program keys for multiple timing selections.

·   Tri-colored LED indicator for diagnostics.

·   Direct and indirect flame sense compatible.

·   Universal design for maximum versatility.

·   Surface mount or 4” x 4 junction box

Application:

·   Gas-Fired Non-Integrated

·   Forced-Air Furnaces and Boilers

Electrical Rating:

·   Input 18 to 30 VAC, 25 VAC nominal

·   Max. Input Current @ 25 VAC; 200mA @ 25°C

Relay Load Settings:

·   Valve Relay: 1.5 amps @ 25 VAC 60 Hz .6pf

·   Ignitor Relay: 6.0 amps @ 120 VAC 60 Hz resistive

Flame Current Requirements:

·   Min. current to insure flame: 2 µADC

·   Min. current for non-detection: 0.2 µADC

·   Max. allowable leakage resistance: 100 M Ohms

Kit Includes:

·   Program Keys

·   Mounting Hardware

·   Double-Sided Foam Back Tape (for ease of installation)

·   Extensive Cross-Reference Guide

·   Color-Coded Timing Label

·   Pre-Printed Hanging Carton

·   Instructions in English/Instrucciones en Espanol