HVAC > Controls > Ignition Controls & Modules > White Rodgers > Universal Silicon Carbide Integrated Furnace Control
| Additional Information | |
|---|---|
| Cool Delay to Fan | |
| Off | 45, 90 |
| On | 5 |
| Off | 60, 90, 120, 180 |
| On | 30, 45 |
| Ignition Activation Period | 1 |
| Initial Warm-up | 17 |
| Input Voltage | 25 VAC 50 / 60 Hz |
| Inter-Purge | 60 |
| Lockout | 300 |
| Operating Humidity | 5% to 93% non-condensing RH |
| Operating Temp | -40° to +175°F |
| Post-Purge | 15 |
| Pre-Purge | 30 |
| Retries | 2 Times |
| Trial for Ignition | 4 |
| Valve Sequence | 12 |
|
Features: · Universal Silicon Carbide Integrated Ignition Control · Replaces 50A55-120, -143, -285, -286, -288, -438, -571, -574 · Diagnostic LED. · Additional Jumpers to Extend the Length of the Connections. · Includes flash code diagnostics. · Fused to protect low voltage system transformers. · Includes mounting hole template. · Adjustable blower relay. · Air Cleaner Tap. · Humidifier Tap, Twin. |
Application: · Gas-Fired Forced-Air Furnaces with Integrated. · Furnace Control Module with a Silicon. · Carbide Ignitor. Electrical Rating at 77°F (25°C): · Input Voltage 25 VAC, 50/60 Hz. · Max. Input Current (@ 25 VAC) 0.45 amp. Relay Load Ratings: · Valve Relay 1.5 A @ 25 VAC, 50/60 Hz, 0.6f. · Ignitor Relay 6.0 A @ 120 VAC, 50/60 Hz (resistive). · Inducer Relay 2.2 FLA-3.5 FLA @ 120 VAC. · Circulator Relay 14.5 FLA-25.0 FLA @ 120 VAC. |